Cambex AIX PC2000 Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
FibreQuik - Fibre Channel Adapter User Guide
lscfg -vl scsi4 should print more information for a card:
DEVICE LOCATION DESCRIPTION
scsi4 20-58 Cambex ...
Manufacturer................CAMBEX
Machine Type and Model......PC1000F
ROS Level and ID............V2.01.19
Serial Number............... 579
Displayable Message.........Cambex ...
Network Address.............500502E010000243
Device Specific.(Z0)........Build:TMFtL
Device Specific.(Z1)........1.5.13.0
Device Specific.(YL)........P1-I1/Z1
lsattr -El scsi4 should print the attributes for a card.
These are also displayed by SMIT in Change / Show
Characteristics of an Adapter.
bus_io_addr Bus address of board I/O registers
bus_intr_lvl Bus interrupt level
intr_priority Interrupt priority
id Adapter card loop ID
exec_throttle Max commands per port
max_iocb Max bufers per port
retry_delay Delay amount after bus reset (sec)
login_on_lip Login all devices after LIP
full_duplex Use open full duplex (OPNyx)
topology_list Prioritized topology list
frame_size Max payload frame length
infinity Command timeout infinity (sec)
dma_window DMA window size for 64 bit PCI
GHz Fibre channel rate in GHz
sw_fc_class Class of service
devtype_exclude SCSI device type exclude list
logout_delay Delay amount after device logout
BDR_mask Mask bus device resets
ID may be used to set a hard card loop ID if required.
Exec_throttle may be used to limit simultaneous I/Os to avoid
"device busy" errors.
Max_iocb is not used.
- 9 -
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 17

Commentaires sur ces manuels

Pas de commentaire