Storage System Configuration
The above activities need to be done prior to going to the next section.
Storage System Configuration
Refer to (for example) chapter one of the BladeStore Storage Manager
Installation Guide P/N 96098 for doing the various storage management
steps. Upgrade information will be added to the CRC or engineering web
pages to provide assistance.
The following is preconfiguration information for a new installation. Information
for an existing storage system is provided on page 9.
Note: For all installations/upgrades where software components are being
changed, the following procedures must be done prior to any software
modifications. This is to ensure a clean removal/install of software
components, which may fail if devices are being accessed or viewed.
- stop access to storage devices
- removal of devices on the AIX host (not the storage array)
- disconnection of cables, as appropriate
Preconfiguring storage systems on new installations
The user needs to determine whether or not they are going to use failover.
There are separate NVSRAM host selections for enabled and disabled
failover. The differences are that in the non-failover NVS host setting, the
unowned LUNs are only presented from the owning controller. The failover
setting presents all LUNs down both paths, and depends on the HBA failover
driver to determine the path presented to the O/S.
The standard method of preconfiguring the storage system should be followed
prior to attaching to the host. Make sure that the FC cables are NOT
connected to the HBAs. This is to ensure that no disks are visible until the
entire software configuration is completed. When the software configuration
procedure is completed, then the cables will be connected and devices
scanned for with the cfgmgr command.
1. Run the following commands.
rmdev -Rdl fcs0
rmdev -Rdl fcs1
Make sure that all devices were removed and no error messages exist
about devices being busy or accessed. If there are errors, disconnect
cables and reboot.
2. Disconnect the FC cables from the HBAs.
3. Using SMclient 8.4x on the AIX host or any attached management station
with SM 8.4x or higher attached to the ethernet ports, download the correct
type and latest version of firmware and NVSRAM (if needed) to both
controllers. Download the firmware first, followed by the NVSRAM.