96107 Fourth Edition 9
StorageTek Proprietary
Storage System Configuration
and the access volume is visible, it will corrupt access to the
StorageTek array. Check if the packages are installed by running the
command:
lslpp -L devices.fcp.disk.array.*
If there is no IBM storage array connected in the architecture, we
recommend removing the AIX packages as follows.
installp -u devices.fcp.disk.array.*
This will allow you to map and use the access LUN for inband storage
management operations if you chose. If AIX software patches are
applied, check if the packages were reinstalled and remove them if
they were.
Upgrading an Existing Configuration
If upgrading an existing storage system that is installed and configured on AIX,
or upgrading software on the AIX host; perform the following actions to
remove existing devices on the AIX host prior to doing any software
modifications. A complete backup of data should be performed prior to this
procedure.
If any of the following steps do not complete and indicate device
busy, do not proceed until the application that is using the device
is stopped. For example you may need to do an SMagent stop
command to stop usage of the access LUNs, stop file system
access by applications, or cd out of a mounted file system. All
devices must be successfully unmounted, varied off, and removed
prior to continuing with software upgrades, otherwise major host
corruption will occur.
1. Unmount any mounted file systems using the umount command or
smit
2. Vary offline any volume groups using varyoffvg or smit
3. If using inband storage management, run the following command.
SMagent stop
4. If using Cambex DPF failover driver, run the following command.
stopsrc -s cbxdpfar
5. Determine the HBAs being used by using the lsdev –Cc adapter
command.
6. Remove the adapters and scsi devices using the rmdev –Rdl fcs(n)
for IBM HBAs, or rmdev –Rdl fscsi(n) for Cambex HBAs
Example for an IBM HBA